Evotech Sigma CP 2,3 & 8 Control Panel

Easy to install, the Sigma CP is available with two, four or eight detection zones in standard or installation saving, ‘two-wire’ versions.

Part Number 600CP-S Categories ,

Talk to our specialists

Description

The extensive range of configuration features available ensure suitability for new installations or panel replacements on older systems. Configuration options are stored in non-volatile memory and are easily accessed via an intuitive user interface, which enables the configuration data to be viewed and changed efficiently. Sigma CP control panels are compatible with most standard, conventional detectors, call points and sounders and are also compatible with ‘two wire’ detector bases from Apollo and Hochiki.

 

Powerful Features

The simple and intuitive programming interface on Sigma CP panels allows simple configuration of many parameters by entering simple codes which are listed on the inner door look up table and in the operation and maintenance manual.

Connectivity

Sigma CP control panels have a dedicated ‘two-wire’ serial bus for connection of repeater panels, ancillary relay boards or zonal sounder extension boards. Up to seven units may be connected to the serial bus which can be up to 1200 metres in length.

Ease of Installation

The elegant and simple construction of the panel enables the chassis to be completely dismantled by removing just two screws.

Additional information

Product Model

, ,

Scorpion ASD Head Unit

Scorpion ASD Head Unit

Scorpion is an innovative solution for functionally testing any hard-to-access smoke detector, whether that is an aspirating smoke detection
(ASD) system or a point detector.
A Scorpion head unit is a smoke generator that is installed next to a detector, and when required, generates smoke that is directed toward the detector for a functional test of the device.

Scorpion Point Head Unit

Scorpion Point Head Unit

Scorpion is an innovative solution for functionally testing any hard-to-access smoke detector, whether that is a point detector or aspirating smoke detection
(ASD) system.
A Scorpion head unit is a smoke generator which is installed next to a detector, and when required, generates smoke which is directed towards the detector for a functional test of the device.

C-TEC CFP761 Network Driver Card

CFP Network Driver Card (CFP761)

  • An optional system expansion device for use with CFP Standard and CFP AlarmSense conventional fire panels.
  • Allows the connection of up to eight CFP760 Repeaters (one CFP761 required per Main, all CFP760 repeaters include a CFP761 as standard).
C-TEC XFP761 Network Driver Card

XFP Network Driver Card (XFP761)

  • An optional system expansion device for use with C-TEC’s XFP Single Loop 16 Zone addressable fire panels.
  • Allows the connection of up to eight XFP Repeaters or eight XFP Main panels (any mix).