Speak to our experts

Speak to our experts

+44 (0) 203 141 0999

Hochiki Dual Sounder Controller – DIN Enclosure with SCI

CHQ-DSC2/DIN(SCI)

Part Number CHQ-DSC2/DIN(SCI) Categories , , ,

Talk to our specialists

Description

Model CHQ-DSC2/DIN(SCI) is a Dual Sounder Controller, which has been designed to provide two sounder outputs (that can be driven separately) with full fault monitoring. The monitored input can be used for local power supply fault monitoring or as a general-purpose input. The unit utilises simple DIL switches for reliable addressing.

Key Features

  • Single loop address
  • Two independent sounder circuits
  • Each circuit fully monitored for open and short circuit faults
  • Each alarm circuit fused at 1 A
  • Auxiliary monitored input
  • Outputs are synchronised and can be driven continuously or intermittently
  • 24 Vdc auxiliary power required
  • Boxed module version available
  • Both models feature an integral short-circuit isolator
  • Both models approved by LPCB & VdS
Scorpion ASD Head Unit

Scorpion ASD Head Unit

Scorpion is an innovative solution for functionally testing any hard-to-access smoke detector, whether that is an aspirating smoke detection
(ASD) system or a point detector.
A Scorpion head unit is a smoke generator that is installed next to a detector, and when required, generates smoke that is directed toward the detector for a functional test of the device.

Scorpion Point Head Unit

Scorpion Point Head Unit

Scorpion is an innovative solution for functionally testing any hard-to-access smoke detector, whether that is a point detector or aspirating smoke detection
(ASD) system.
A Scorpion head unit is a smoke generator which is installed next to a detector, and when required, generates smoke which is directed towards the detector for a functional test of the device.

C-TEC CFP761 Network Driver Card

CFP Network Driver Card (CFP761)

  • An optional system expansion device for use with CFP Standard and CFP AlarmSense conventional fire panels.
  • Allows the connection of up to eight CFP760 Repeaters (one CFP761 required per Main, all CFP760 repeaters include a CFP761 as standard).
C-TEC XFP761 Network Driver Card

XFP Network Driver Card (XFP761)

  • An optional system expansion device for use with C-TEC’s XFP Single Loop 16 Zone addressable fire panels.
  • Allows the connection of up to eight XFP Repeaters or eight XFP Main panels (any mix).

Need to talk to a member of the team?

Our support and sales team would love to help with any questions. Feel free to leave your details and we will get back to you shortly.