C-TEC Conventional CFP 2-8 Zone Fire Panel

Part Number CFP702-4, CFP704-4, CFP708-4 Categories ,

Talk to our specialists

Description

Certified to EN54 parts 2, 4 and 13, C-TEC’s CFP 2, 4 and 8 zone conventional fire alarm panel offers an array of user and installer-friendly features at a very competitive price.

Additional information

Specification

Approvals: Certified to EN54-2/4 by the LPCB (176b) / (0832-CPD-1704)
Mains Supply: 230 V 50/60 Hz
Mains Rated Current: 350 mA maximum
Internal Power Supply: 19 V – 28.5 V (27 V nominal). Ripple 7 V maximum (battery fault)
Total Output Current Limited to: 1.5 A @ 230 Vac (lmaxA eq 146 mA)
Quiescent Current: 25 mA (mains failed, internal sounder active, PSU & gen fault LED lit)
Alarm Voltage: 27 V max 20 V min (final battery voltage)
Max Battery Size & Type: 2 x 12 V 3.2 Ah VRLA connected in series. Min battery size 1.2 Ah
No. of Detector Zone Circuits: 8 (Max length per circuit is 500 m)
Call Point Resistor Value: 470 to 680
Max Devices per Detector Zone: 25 detectors (or 32 detectors/manual call points combined)
No. of Conventional Sounder Circuits: 4 (max length per circuit is 500 m)
EOL Resistor Value: 6800 – 5% ToL 0/25 W (blue, grey, red, gold)
Max Sounder Output Current: 4 x 200 mA (800 mA total)
Aux Relays: Two: (1) Aux. Fire, (2) Fault, Volt free single pole changeover. Max switch current 1 A; Max switch voltage 30 Vdc
Open Collector Outputs: Two: (1) Reset (Active during reset cycle), (2) Remote (Active during any unsilenced fire condition provided all relevant delays have expired). Max sink current 30 mA. Max open circuit voltage 27 Vdc.
Other Outputs: 24 V Aux. Power (Protected by a resettable fuse. 100 mA min. hold current. Resets when fault removed
Aux Inputs: Two: (1) Class Change (constant sounders), (2) Remote (active during any unsilenced fire condition provided all relevant delays have expired)., Max. sink current 30 mA, Max. open circuit voltage 27 Vdc
Engineer (AL3) Functions: Program coincidence (double knock) , Invoke One Man Walk Test; Program Delays; Set up zones for non-latching operation; Program sounders to resound (or not resound) when a new zone enters alarm; Enter fault diagnostic facilities.
Expansion Connections: Yes – for optional network driver cards (one required per repeater system) , relay output cards and EN54-13 sounder circuit interface boards.
Product Dimensions (mm): 380 W x 235 H x 96 D
Construction & Finish: Plastic lid and base – RAL7035 textured
IP Rating: IP30
Weight: 1.75 kg (without batteries)
Operating Conditions / Temperatures: -5 C to +40 C (Max RH: 95%)

SOC-E3N(WHT)

Hochiki Conventional Photoelectric Smoke Detector – White

The SOC-E3N(WHT) is an optical Smoke Detector, which is fully compatible with the majority of existing Conventional systems. The SOC-E3N incorporates Hochiki’s unique High Performance photoelectric smoke chamber removing the need to use Ionisation Detectors in the majority of applications.

DCD-AE3

Hochiki Conventional Rate of Rise Heat Detector – White

DCD-AE3 is a Rate of Rise Heat Detector with a 60 °C fixed temperature element using a thermistor and linearising circuit to provide an accurate linear response Heat Detector.

ALN-ENWHT

Hochiki Photoelectric Smoke Sensor – White Case

Model ALN-EN-WHT is a Photoelectric Smoke Sensor, which is fully compatible with Hochiki’s ESP Analogue Addressable Protocol. The ALN-EN incorporates Hochiki’s newest High Performance Chamber Technology removing the need to use Ionisation Smoke Sensors in the majority of applications.

Hochiki-HCP-EBLU-SCI

Hochiki Addressable Call Point with SCI – Blue

Model HCP-E(SCI) is a Manual Call Point with integral short-circuit isolator, which is fully compatible with Hochiki’s ESP analogue addressable protocol.