Speak to our experts

Speak to our experts

+44 (0) 203 141 0999

Sygno-fi Output Module

Part Number SYG-OM -

Talk to our specialists

Description

The SYG-OM Sygno-fi Output Module has been designed to allow easy control of a variety of third party equipment including access control doors, ventilation plant and fire extinguishing systems.

Additional information

Further Description

The unit is powered entirely from its internal battery supply and is fitted as standard with both a set of change over relay contacts and a 12/24V dc output.

The output is capable of supplying power for operating low current third party equipment directly from the internal batteries.

Key Features

• Bi-directional wireless communication
• Output circuits are fully supervised for alarm and fault conditions
(utilizing EOL resistors)
• Can be used with Sygno-fi addressable and conventional translators
• Change over relay and 12/24V output functionality
• On site programmable
• 22 pairs of field channels
• Dual channel redundancy
• Long communication range (≅ 1 km in open air)
• 5 year expected battery life (application dependent)
• Utilises dual low cost lithium battery
• Easy scan & link programming option
• 3rd party approval to EN54-18 and EN54-25
• 5 year product warranty

Download the Sygno-fi Digital Brochure below:

Sygno-fi Digital Brochure - 2022

SOC-E3N(WHT)

Hochiki Conventional Photoelectric Smoke Detector – White

The SOC-E3N(WHT) is an optical Smoke Detector, which is fully compatible with the majority of existing Conventional systems. The SOC-E3N incorporates Hochiki’s unique High Performance photoelectric smoke chamber removing the need to use Ionisation Detectors in the majority of applications.

DCD-AE3

Hochiki Conventional Rate of Rise Heat Detector – White

DCD-AE3 is a Rate of Rise Heat Detector with a 60 °C fixed temperature element using a thermistor and linearising circuit to provide an accurate linear response Heat Detector.

ALN-ENWHT

Hochiki Photoelectric Smoke Sensor – White Case

Model ALN-EN-WHT is a Photoelectric Smoke Sensor, which is fully compatible with Hochiki’s ESP Analogue Addressable Protocol. The ALN-EN incorporates Hochiki’s newest High Performance Chamber Technology removing the need to use Ionisation Smoke Sensors in the majority of applications.

Hochiki-HCP-EBLU-SCI

Hochiki Addressable Call Point with SCI – Blue

Model HCP-E(SCI) is a Manual Call Point with integral short-circuit isolator, which is fully compatible with Hochiki’s ESP analogue addressable protocol.

Need to talk to a member of the team?

Our support and sales team would love to help with any questions. Feel free to leave your details and we will get back to you shortly.