IR³ Flame Detector – Stainless Steel

Talk to our specialists

Description

These flame detectors give excellent immunity to false flame sources both indoors or out. They have internal self-test sources that check the detector’s operation when remotely instructed.

They can operate on a conventional 2-wire (14-28 Vdc) fire systems or 4-20mA process control systems. Relay contacts are also available for Fire and Fault signals. The detectors’ operating modes can be user selected giving a choice of alarm currents, response times, latching or non-latching outputs and sensitivity. The detectors have a maximum ambient operating temperature of 55°C.

 

Key Features

  • Excellent immunity to false sources
  • Suitable for indoor and outdoor areas
  • Detects invisible flames from fuels such as Hydrogen and other inorganic fuels
  • Selectable response speed
  • Optical self-test
  • Low power consumption
  • Approved to EN54-10:2002
Scorpion ASD Head Unit

Scorpion ASD Head Unit

Scorpion is an innovative solution for functionally testing any hard-to-access smoke detector, whether that is an aspirating smoke detection
(ASD) system or a point detector.
A Scorpion head unit is a smoke generator that is installed next to a detector, and when required, generates smoke that is directed toward the detector for a functional test of the device.

Scorpion Point Head Unit

Scorpion Point Head Unit

Scorpion is an innovative solution for functionally testing any hard-to-access smoke detector, whether that is a point detector or aspirating smoke detection
(ASD) system.
A Scorpion head unit is a smoke generator which is installed next to a detector, and when required, generates smoke which is directed towards the detector for a functional test of the device.

C-TEC CFP761 Network Driver Card

CFP Network Driver Card (CFP761)

  • An optional system expansion device for use with CFP Standard and CFP AlarmSense conventional fire panels.
  • Allows the connection of up to eight CFP760 Repeaters (one CFP761 required per Main, all CFP760 repeaters include a CFP761 as standard).
C-TEC XFP761 Network Driver Card

XFP Network Driver Card (XFP761)

  • An optional system expansion device for use with C-TEC’s XFP Single Loop 16 Zone addressable fire panels.
  • Allows the connection of up to eight XFP Repeaters or eight XFP Main panels (any mix).