C-TEC Conventional CFP 2-8 Zone Fire Panel

Part Number CFP702-4, CFP704-4, CFP708-4 Categories ,

Talk to our specialists

Description

Certified to EN54 parts 2, 4 and 13, C-TEC’s CFP 2, 4 and 8 zone conventional fire alarm panel offers an array of user and installer-friendly features at a very competitive price.

Additional information

Specification

Approvals: Certified to EN54-2/4 by the LPCB (176b) / (0832-CPD-1704)
Mains Supply: 230 V 50/60 Hz
Mains Rated Current: 350 mA maximum
Internal Power Supply: 19 V – 28.5 V (27 V nominal). Ripple 7 V maximum (battery fault)
Total Output Current Limited to: 1.5 A @ 230 Vac (lmaxA eq 146 mA)
Quiescent Current: 25 mA (mains failed, internal sounder active, PSU & gen fault LED lit)
Alarm Voltage: 27 V max 20 V min (final battery voltage)
Max Battery Size & Type: 2 x 12 V 3.2 Ah VRLA connected in series. Min battery size 1.2 Ah
No. of Detector Zone Circuits: 8 (Max length per circuit is 500 m)
Call Point Resistor Value: 470 to 680
Max Devices per Detector Zone: 25 detectors (or 32 detectors/manual call points combined)
No. of Conventional Sounder Circuits: 4 (max length per circuit is 500 m)
EOL Resistor Value: 6800 – 5% ToL 0/25 W (blue, grey, red, gold)
Max Sounder Output Current: 4 x 200 mA (800 mA total)
Aux Relays: Two: (1) Aux. Fire, (2) Fault, Volt free single pole changeover. Max switch current 1 A; Max switch voltage 30 Vdc
Open Collector Outputs: Two: (1) Reset (Active during reset cycle), (2) Remote (Active during any unsilenced fire condition provided all relevant delays have expired). Max sink current 30 mA. Max open circuit voltage 27 Vdc.
Other Outputs: 24 V Aux. Power (Protected by a resettable fuse. 100 mA min. hold current. Resets when fault removed
Aux Inputs: Two: (1) Class Change (constant sounders), (2) Remote (active during any unsilenced fire condition provided all relevant delays have expired)., Max. sink current 30 mA, Max. open circuit voltage 27 Vdc
Engineer (AL3) Functions: Program coincidence (double knock) , Invoke One Man Walk Test; Program Delays; Set up zones for non-latching operation; Program sounders to resound (or not resound) when a new zone enters alarm; Enter fault diagnostic facilities.
Expansion Connections: Yes – for optional network driver cards (one required per repeater system) , relay output cards and EN54-13 sounder circuit interface boards.
Product Dimensions (mm): 380 W x 235 H x 96 D
Construction & Finish: Plastic lid and base – RAL7035 textured
IP Rating: IP30
Weight: 1.75 kg (without batteries)
Operating Conditions / Temperatures: -5 C to +40 C (Max RH: 95%)

OMN-REP

Omnis Repeater Panel

Networked Repeater for use with any Omnis control panel. The repeater’s compact styling makes it ideal for all small and medium site requirements.

OMN-V1002

Omnis 1-4 Loop Fire Control Panel – Odyssey Protocol

The Omnis 1-4 loop analogue addressable control panels have been developed to provide a simple to use and cost effective, robust solution for the intelligent fire systems market.

OMN-V1002

Omnis 1-4 Loop Fire Control Panel – Eurotech Protocol

The Omnis 1-4 loop analogue addressable control panels have been developed to provide a simple to use and cost effective, robust solution for the intelligent fire systems market.

OMN-V1001

Omnis 1-2 Loop Fire Control Panel – Odyssey Protocol

The Omnis 1-2 loop analogue addressable control panels have been developed to provide a simple to use and cost effective, robust solution for the intelligent fire systems market.

Need to talk to a member of the team?

Our support and sales team would love to help with any questions. Feel free to leave your details and we will get back to you shortly.